Loading... Please wait...

Our Newsletter


Welch Allyn CP 150 12-Lead Resting Electrocardiograph

  • Image 1
Price:
$1,628.00
Shipping:
$60.00 (Fixed shipping cost)
Quantity:
Bookmark and Share


Product Description

  • Dimensions: 15" x 14.1" x 5.4" (381 mm x 358 mm x 136 mm).
  • Weight: 11.7 lb (5.3 kg).
  • Keyboard Type (power button): Polyester overlay.
  • Display Type: TFT, 18 cm (7") color touchscreen.
  • Display Resolution: WVGA, 800 x 480.
  • Instant On: Yes.
  • Thermal Paper: Z-fold 8.3" x 11" (21 cm x 28 cm); 200 sheets.
  • Gain Settings:
    • Auto ECGs: 2.5, 5, 10, or 20 mm/mV, AUTO.
    • Rhythm ECGs: 10, 25, or 50 mm/mV.
  • Lead Configurations: Standard, Cabrera.
  • Interpretation Algorithm: MEANS (Modular ECG Analysis System).
  • Common Mode Rejection Ratio (CMRR): > 80 dB.
  • Input Impedance: > 2.5 Ω
  • Patient Leakage: < 10 μA (normal condition), < 50 UA (single fault condition).
  • Dynamic Range: AC differential +/- mV, DC offset +/- 300 mV.
  • Resolution: 2.5 μV.
  • A/D Conversion: 16 bits.
  • Heart Rate Range: 30 to 250 bpm.
  • Report Formats, Internal Printer:
    • Auto:
      • 3x4-2.5s @ 25 mm, 3x4-2.5s @ 50 mm, 3x4+1R-2.5s @ 25 mm.
      • 3x4+3R-2.5s @ 25 mm, 3x4-5.0s @ 25 mm, 3x4-5.0s @ 50 mm.
      • 6x2-5.0s @ 25 mm, 6x2-5.0s @ 50 mm,12x1-10.0s @ 25 mm.
    • Average Cycles: 3x4+3R @ 25 mm, 3x4+3R @ 50 mm, 6x2+1R @ 25 mm, 6x2+1R @ 50 mm, no print.
  • ECG Storage (in test directory): At least 100 ECG tests.
  • Frequency Range: 0.3 to 150 Hz.
  • Digital Sampling Rate: 8,000 samples/second/channel for data acquisition; 500 / 1,000 samples/second/channel for adult/pediatric ECG data analysis and storage.
  • Pacemaker Detection: ANSI/AAMI EC11.
  • Lead Detection: Lead off and noise.
  • Power Requirement: Universal AC power supply ~110–240 V, ~50/60 Hz, 1.5 A maximum.
  • AC Fuses: Time-lag type, 2.0-amp 250-V rating, Littlefuse 0218002P or equivalent.
  • Protection Against Electric Shock: Class I, internally powered type CF.
  • Rechargeable Battery: 10.8 V, 6.75 Ah (73 Wh), 9-cells Lithium-Ion. Recharge time to 90% capacity: 4 hrs. Full charge capacity—25 ECG tests @ 20 minutes/test. 8 hours of continuous operation or 250 continuous ECGs.
  • Filters:
    • High-Performance Baseline: 0.5 Hz.
    • Muscle Tremor: 35 Hz.
    • AC Interference: 50 Hz or 60 Hz.
  • Standard Connectivity: 1 USB client, 4 USB hosts and Ethernet.
  • Connectivity Options:
    • DICOM-compatible platforms (EMR, PACS, CVIS): Bidirectional capability with worklist download and ECG waveform upload. No middleware/software needed.
    • PDF to network folder, PDF to USB drive.
    • Electronic medical records: Through the Welch Allyn CardioPerfect WorkStation software. Middleware required (HL7 connectivity optional).
  • Electrodes: Rigorously tested for conductivity, adhesion and hypoallergenic qualities; exceed all AAMI standards.
  • Power Cable: Meets or exceeds Type SJT.
  • Patient Cable and Leads: Meets or exceeds ANSI/AAMI EC53, EN/IEC 60601-2-25 and EN/IEC 60601-2-51.
  • Environmental Operating Conditions:
    • Temperature: 10° to 40°C (50° to 104°F).
    • Relative Humidity: 15 to 95% noncondensing (30 to 70% for printing).
    • Atmospheric Air-Pressure Limits: 700 to 1060 hPa (525 to 795 mmHg).
  • Environmental Storage Conditions:
    • Temperature: -20° to 50°C (-4° to 122°F).
    • Relative Humidity: 15 to 95% noncondensing.
    • Atmospheric Air-Pressure Limits: 700 to 1060 hPa.
  • Mode of Operation: Continuous.

 


Find Similar Products by Category